The SafeX Flame Jet flame box is another SD supported DMX device. Like all flame boxes it has a safety channel and a trigger channel. In order for the flame box to operate, the safety channel must be turned on before any trigger commands will activate. For safety reasons we must also turn the safety channel back off at the end of the script. The safety and triggers may be turned on or off any number of times as long as the safety is on before any trigger cues are executed. The Flame Jet has three commands for this: FlameJetSafetyOn, FlameJetTrigger and FlameJetSafetyOff. Note that multiple Flame Jet devices may use the same safety channel.
SD Column Name |
DMX |
Note |
TYPE |
One of the Flame Jet commands listed below |
|
CONTROL |
Controller |
One DMX controller universe per serial USB connection |
MODULE |
Channel |
Values 1 to 512 are allowed |
DUR |
The duration of this flame |
Must be a value between 00:01 and 10:00 (maximum duration) |
Assuming two Flame Jet boxes are configured with safety channel 33 and trigger channel 2 and 17 respectively:
CUE |
HH MM SS FF |
TYPE |
CONTROL |
MODULE |
DUR |
Event Description |
1 |
00 00 00 00 |
FlameJetSafetyOn |
G2 |
33 |
00:00 |
Set channel 33 to FlameJet safety |
2 |
00 00 05 00 |
FlameJetTrigger |
G2 |
2 |
00:15 |
Flame on device 2 for half sec |
3 |
00 00 05 00 |
FlameJetTrigger |
G2 |
17 |
00:15 |
Also start device 17 for same |
4 |
00 01 00 00 |
FlameJetTrigger |
G2 |
2 |
05:00 |
Flame on device 2 for 5 sec |
5 |
00 05 00 00 |
FlameJetSafetyOff |
G2 |
33 |
00:00 |
Disable both 2 and 17 |
You should always turn the Flame Jet safety on for at least 1 second before any trigger events in order to give the flame box time to get activated.