Export a Script to other systems

Parent Previous Next

Export a Script to other systems

Exports a file to Fireone (*.fir), Galaxis (*.gs2), Pyroleda (*.shw), Explo(*.shw), Cobra, FIREMASTER, fireTEK (* .csv), Piromac.

The column order and configuration is the same as in Show Director Script.

If you want to export All Columns, you need to use the File Menu function "Save As> Excel. xls, or .csv"



FireOne Columns Correspondence (.xls)


FireOne

F1 Type

VSD Column

Comment

ID

AutoIncrementing


AutoIncrementing - NOT CUE, CUE IS LOST

ScriptTime

float



Position

Char(10)

POS

DATA LOSS 64 -> 10

Qty

small int

QTY


BreakTime

float



Duration

float

DUR


Priority

small int

CGHZ

Defaults to '1' else CGHZ

Cost

BCD

PRICE1


Location

Char(8)

POS

DATA LOSS 64 -> 8

Comment

Char(60)

Event Description

DATA LOSS 128 -> 60

LaunchTime

float



Description

Char(80)

Effect Description

DATA LOSS 128 -> 80

ProductNumber

Char(20)

REF

DATA LOSS 50 -> 20

Size

Char(12)

CAL

DATA CONVERSION  Int -> string

Color

Char(14)



VendorNumber

Char(20)

MFG

DATA LOSS 64 -> 20

Type

Char(15)

TYPE

DATA LOSS 36 -> 15

ScriptTimeMS

int

MS


LaunchTimeMS

int

MS - PFT


DelayTimeMS

int


Hardcoded to '0'

ScriptTimeText

Char(14)

MS


LaunchTimeText

Char(14)

MS - PFT


DelayTimeText

Char(14)


Hardcoded to "00:00:00.00"

Effects

Char(6)

ANGLE

DATA LOSS 64 -> 6

Event

small int

MACRO


Slat

int

MODULE


Cue

int

PIN


Length

Int



SayWhen

int



SayWhenText

Char(14)



SayWhat

Char(50)



Conflict

Char(10)



PyroSlat

Char(4)



PyroCue

Char(2)






GALAXIS


Galaxis Columns Correspondence (.xls)


field - Version 2

Galaxis Name

your interpretation

Prefered Galaxis Name

VSD Column

Comment

Value

Sample

Sample

Sample

Sample

Description

(Field #0)

Ignition time count

0

Cue

CUE

starting with 1

1 - 999





Cue 1 starts normally at 00:00:00, if the ignition time is the same we have the same cue number

(Field #1)

Dt

1

dt

NEXT

as an integer representation of 1/100 seconds

0 - 99990

0,91s = 91

2,10s = 210




(Field #2)

Ignition time

2

Fire Time

MS - PFT

as an integer representation of 1/100 seconds

0 -

3:55:49 = 35594

2:53:04 = 25304

9:57:75 = 95775

10:03:88 = 100388

the whole script is sorted by ignition time

(Field #3)

Effect time

3

Effect Time

MS - PFT

as an integer representation of 1/100 seconds

0 -

same as ignition time





(Field #4)

Prefire duration

4

PFT

PFT

in the format 0,00

0.00 -

1.55 = 1.55

2.20 = 2.20






5

Duration 1

DUR

in the format 0,00

0.00 -

1.20




If you have a three times color changing effect = duration of effect 1



6

Duration 2


in the format 0,00

0.00 -

2.10




If you have a three times color changing effect = duration of effect 2



7

Duration 3


in the format 0,00

0.00 -

1.25




If you have a three times color changing effect = duration of effect 3

(Field #8)

Step cue

8

S Cue


if two cues are to close together like < 0.30 s we have to use the step cue and step delay

1 - 999






(Field #9)

Step delay

9

S Delay


as an integer representation of 1/100 seconds

0.01 - 99.99

229.96 = 22996

431.46 = 43146




(Field #10)

Category

10

Category


as a string






not really used

(Field #12)

Effect Name

11

Item

TYPE

as a string









12

Description

EFFECT DESC

as a string


Peony color changing




free text for the user

(Field #13)

Caliber

13

Size

CAL

as a string from VSD float

5 or 125

5 as inch or 125 as mm




free value for the user



14

Effect 1

CUSTOM8

as a string


Peony color changing




free text for the user



15

Color 1


as a string


red




free text for the user



16

Effect 2


as a string


Peony color changing




free text for the user



17

Color 2


as a string


blue




free text for the user



18

Effect 3


as a string


Peony color changing




free text for the user



19

Color 3


as a string


green




free text for the user



20

Shots


as an integer


16




Shots from a cake box



21

Pcs

QTY

as an integer






if you shoot more then one simultaneously

(Field #22)

Launch Position

22

Position

POS

as a string


left; center; right




Firing position

(Field #23)

Angle

23

Angle

ANGLE

Angle in degrees, followed by symbol font arrow characters dG, dF, and dH, e.g., up = 0dG , left = 0dF, right = 0dH



with the PyrotecComposer.ttf font you can see an arrow in the right direction and the value in degrees



24

Fan Type


as a string






free text for the user



25

Fan Name


as a string






free text for the user



26

Tube No.


as a string






free text for the user



27

Igniter


as a string






free text for the user

(Field #28)

Device number

28

Device ID #

MODULE

ID number of the receiver, receiver 1 to 999

1 - 999






(Field #29)

Output number

29

Output #

PIN

depends on the device and extension module like Matrix Module 50 or 100 Output

1 - 100 (1 - 50)






(Field #30)

SC-ID

30

SC-ID

AutoCreated

unique incrementing value + 10000

10001 -








31

DB-ID


unique ID number of the database effect









32

Rising Height


as a string






free text for the user



33

Diameter


as a string






free text for the user



34

BAM Number

CUSTOM1

as a string






free text for the user



35

ADR Class.


as a string






free text for the user



36

UN Number

CUSTOM2

as a string






free text for the user



37

Chipher


as a string






free text for the user



38

Net weight

CUSTOM3

in the format 0,00






free value for the user



39

Gross weight

CUSTOM4

in the format 0,00






free value for the user



40

S.D. horizontal


in the format 0,00






free value for the user



41

S.D. vertical


in the format 0,00






free value for the user

(Field #42)

Product ID

42

Item No.

REF

as a string






free text for the user



43

Supplier

MFG

as a string






free text for the user



44

Producer


as a string






free text for the user



45

Price

PRICE1

in the format 0,00

0.00

23.50




free value for the user



46

Calc. Factor

PRICE2

in the format 0,00

0.00

1.40




we calculate Price (CP): 1.00 x 1.40 (Calc. Factor) = SP



47

Description

CUSTOM6

as a string






free text for the user



48

Information

CUSTOM7

as a string


nice effect




free text for the user



49

Image (Path)

PICTURELINK

as a string






free text for the user



50

Video (Path)

VIDEOLINK

as a string






free text for the user



51

Indoor


0 or 1






free value for the user



52

Outdoor


0 or 1






free value for the user



53

C1


32 bit color value of Color 1

0 - 16777215

0 = black

255 = red

65280 = green

16711935 = magenta




54

C2


32 bit color value of Color 2

0 - 16777215

16777215 = white







55

C3


32 bit color value of Color 3

0 - 16777215








56

Infotext Z1

TYPE

max. 16 characters  of ASCII Characters


gerb step run




Shows the PFC Advanced controller during firing



57

Infotext Z2

EFFECT DESC

max. 16 characters  of ASCII Characters


middle of stage




Shows the PFC Advanced controller during firing



58

Class

CUSTOM5

as a string









59

Stock Place

MAG

as a string









60

ShowSim Effect ID

VISUALREF

ShowSim Effect ID









61

Part List











62

F

MACRO

empty or F






To separate the script; if the controller reads a "F" -> the controller stops and wait till anybody press the fire button. Is sometimes used with life music



63

Layer


as a string









64

Group

GROUP

as a string






the same name belongs to one group; just for editing



65

PAN Angle


same as angle









66

Tilt Angle ShowSim

TILT

translated values for ShowSim from Angle









67

Pan Angle ShowSim

PAN

translated values for ShowSim from Pan Angle










FIREMASTER


Field

Firemaster Name

VSD Column

Comment

1

Cue

Cue


2

Seq

Macro


3

Rif

Group


4

Start

Cue Time

Start + Delay = Cue Time, but Delay is not stored seperately

5

Delay

(See Cue Time Comment)


6

Address

Module / Pin

If Unit/Term is provided it is used otherwise Address is split into Module/Pin

7

Unit

Module


8

Term

Pin


9

Group

Cghz


10

Note

Effect Description

Up to 127 characters

11

11 - 17 UNUSED





EXPLO



Field

Explo Name

VSD Column

Comment

0

Box/Nr

MODULE / PIN

The module (box) and pin (post) number of the shot.

1

Explozeit

MS

The break time of the shot, in the format 00:00.00. (MM:SS.MS)

2

Abstand Zündzeit

NEXT

The delay to the next firing row, in the format 00:00.00. (MM:SS.MS)

3

Effektbezeichnung

Effect Desc

The effect description.

4

Stz.

PFT

The prefire time, in the format 0,0 (comma decimal point).

5

Efz.

DUR

The duration of the effect.  Written as whole number of seconds

6

Efg.

TYPE

The effect category.

7

Stop



8

Stk.

QTY

Quantity.  total number of devices represented by the firing row.

9

Beschreibung

ANGLE

Comment. indicating the angles of the shots, such as ///.

10

Position


"Position"

11

Steighöhe


"Rising Height"

12

Größe

CAL

"Size"

13

Etk.

CUSTOM8

Label text

14

Effekttop


"Effect Top"

15

Gruppe

GROUP

"Group"

16

Bereich


"Area"

17

Winkel

TILT

Angle.

18

Pos.

POS

Launch position.

19

(no name)

REF

20

blank


Just to have an trailing TAB on each line



PYROLEDA


PyroLEDA

Show Director

Notes

“@”


instruction line start character. GEH NOTE will skip all other lines

“cue”


(integer >0) cue id number.  GEH NOTE Autoincrements. if cue is zero then we add a row with 0 time and this whole line in Event Desc and the MACRO is zero

“time”

MS - PFT

(integer >= 0) time in millisecond.

“trigger”

MODE

trigger source can be: MAN, AUTO, SLV

“group”

CGHZ

(integer >= 0 and <= 8) group id. GEH NOTE all values 8-16 will be mapped to 8

“seq”

MODULE

(integer > 0) sequencer id.

“fire”

PIN

integer > 0 (1-32) to turn on fire line, integer <0 to turn it off .  GEH NOTE We can't do negitive pin numbers, see [length]

“fire comment”

Event Desc

text string (can be null).

[“lenght”]

Custom7

optional (can be omitted), integer>0 in milliseconds, duration of pulse. Special value 32768 = infinite (line must be turned off explicitly).  GEH NOTE: Stored in Custom7 as "LINE ON XX" or "LINE OFF" if pin was negative

[“voltage”]

Custom8

optional (can be omitted), integer>0 in Volt, if included, MUST BE Forwarded by the preceding length field GEH NOTE stored in Custom8



FIRETEK


Field

FireTek Name

VSD Column

Comment

1

Module Address

CONTROL


2

Slot Address

MODULE


3

Pin Address

PIN


4

IgnitionTime

MS-PFT

in milliseconds  (Prefire Time, MS - PFT)


Created with the Personal Edition of HelpNDoc: Easy EPub and documentation editor